Hot-Dip Galvanized Steel Coils – DX51D DX52D SGCC S350GD

Categories

Hot-Dip Galvanized Steel Coils

Brand

Hzxy

standard

GB、ASTM、BS、JIS

Width

900-1000 mm

Thickness

0.2-12mm

Length

6-12m

Processing Service

Bending、cutting、welding、Punching

dimensional tolerance

±2%

Delivery period

15-21days

Terms of Payment

L/C, T/T

    Product Details

    Minimum Order Quantity

    2 ton

    Shape

    Plate. Coil

    Production Process

    Cold Rolled、Hot Rolled

    place of dispatch

    port of Tianjin、port of Qingdao

    Sample

    Sample Freely

    serve

    OEM,ODM

    use

    Construction, manufacturing, container, shipbuilding, etc.

    Grade

    SGCC,SGCH,G350,G450,G550,DX51D,DX52D,DX53D

    Surface

    galvanized, shot blasted and primer painted

    Packaging

    strapping with steel strip、wooden case

    What Is a Galvanized Steel Coil

    A galvanized steel coil (also referred to as galvanized coil) is a flat steel product with a continuous zinc or zinc-based metallic coating on its surface. The zinc layer acts as a barrier and, at small exposed areas such as cut edges and scratches, corrodes preferentially as a sacrificial anode to protect the base steel — a single organic coating tends to fail at these locations. It is widely used in building envelopes, home appliance manufacturing, ventilation systems, automotive parts, metal furniture and general fabrication, and is the core material behind galvanized sheet metal coils, GI coil sheet, roofing, purlins, cable trays, ductwork and appliance shells.

    Product Details

    Item

    Hot-dip galvanized (HDG)

    Electro-galvanized (EG)

    Coating weight

    Heavy, commonly Z100–Z275 g/m² total on both sides

    Light, approx. 3–20 µm per side

    Surface condition

    Spangle present; zero-spangle also available; visible zinc crystal pattern

    Uniform and smooth, no spangle

    Outdoor corrosion life

    Long service life; the conventional choice for roofing, cladding and fencing

    Shorter; not intended for long-term outdoor exposure

    Paintability

    Good paintability after pre-treatment; zero-spangle preferred for painting

    Excellent paintability; the common substrate for painted appliance panels

    Weldability

    Fume extraction required during welding; zinc layer needs repair after welding

    Easier to weld, thinner coating

    Cost

    Lower cost per ton of protection

    Higher


    Products for outdoor use, or products roll-formed into roofing and cladding, are usually supplied as hot dipped galvanized steel coils; workpieces that will be painted in the factory, deep-drawn, or subject to inspection for surface uniformity are mostly produced from electro-galvanized material.

    Cold-Rolled Substrate vs Hot-Rolled Substrate

    Item

    Cold-rolled substrate

    Hot-rolled substrate

    Thickness range

    Thinner, generally up to about 3.0 mm

    Greater thickness, commonly from 1.5 mm

    Surface condition

    Smooth surface, tight thickness tolerance

    Rougher surface, visible hot-rolled mill scale texture, wider tolerance

    Typical products

    Appliance shells, deep-drawn parts, substrate for prepainted galvanized steel coil, light roofing sheet

    Structural sections, purlins, guardrails, tubes, truck body components, heavy ductwork

    Key advantage

    Better appearance quality and formability

    Higher strength-to-cost advantage at thicker gauges


    The substrate type also affects the finished surface and the price; stating the grade and the substrate origin together in the purchasing specification helps obtain a more accurate quotation.

    Coating Weight, Surface Condition and Surface Treatment

    Hot-dip galvanized coil is specified by coating weight in grams per square metre, total for both sides. Z100 means the total zinc coating weight on both sides is 100 g/m². Common specifications are Z100, Z180, Z200 and Z275. Differential coatings are also available — for example a heavier coating on the weather face and a lighter one on the underside — which is usually more economical than a heavy coating on both sides. As a rough industry reference, a Z275 coating can last for several decades in a mild inland atmosphere, but its service life is significantly shortened near breaking sea surf or in heavy industrial areas; the actual number of years should be assessed against the real service environment.
    The surface can be supplied with regular spangle, minimized spangle or zero spangle depending on the process, with zero spangle being more suitable for subsequent painting. Surface treatments include passivation, oiling, dry and anti-fingerprint. For shipments to the EU and for buyers with sustainability requirements, chrome-free passivated products are available to meet RoHS and REACH requirements.

    Galvanized Steel Coil Applications and Further Processing

    Galvanized steel coil can be processed into substrate for roofing and wall cladding, cable trays, ceiling profiles, light steel keels, HVAC ducts and air-conditioning components, appliance shells and cabinets, shelving and storage system components, as well as structural sections and some load-bearing members. It also serves as the substrate for prepainted galvanized steel coil. Common processing methods include slitting, cut-to-length, roll forming, bending, punching, stamping and welding.
    The grade selected is usually matched to the severity of the forming operation. The zinc layer has a certain influence on welding conditions and tool wear; large deformation forming may damage the coating at tight bends. When the bend radius is too small on heavily coated products, the risk of coating flaking increases accordingly, so confirming the minimum inside bend radius for the relevant grade and coating weight before tooling goes into production is the more reliable approach. Local exhaust is generally provided during welding, and the zinc layer in the heat-affected zone can be restored with a zinc-rich repair coating.

    Storage, Transport and Handling of Galvanized Steel Coil

    Galvanized steel coil is best stored in a dry, well-ventilated indoor area, raised clear of damp floors, protected from rain, condensation and moisture trapped between the coil wraps. White rust tends to form when freshly galvanized surfaces stay wet for long periods with poor air circulation — for example tightly stacked sheets after rain, or condensation inside a container. Keeping the material ventilated and dry is more effective than simply increasing the coating thickness. During handling, use C-hooks or rated lifting devices matched to the load, secure the coil against rolling and shifting, protect the coil edges and zinc coating from impact, and check the packaging and any signs of water on arrival. On the line, hold-down rolls and controlled uncoiling equipment release the stored energy of a tightly wound coil. Where galvanized steel comes into contact with copper, isolation is the more appropriate approach.

    HZXY Supply and Customization Service

    HZXY is one of the excellent suppliers exporting galvanized steel coils from China, and can arrange galvanized coil orders by grade, size, zinc coating, surface condition and processing requirements.
    ● Coating customization: standard zinc, high zinc and differential coatings; zero spangle, minimized spangle, regular spangle; chromated or chrome-free passivation; oiled, dry, anti-fingerprint
    ● Dimensions and processing: thickness, width, coil ID and coil weight customized as required; slitting, cut-to-length shearing, cutting and recoiling available
    ● Inspection documents: HZXY provides EN 10204 3.1 mill certificates, SGS / BV pre-shipment inspection, and the test reports required by the customer
    Welcome to contact HZXY. Coating weight, substrate type and passivation method have the greatest influence on galvanised steel coil price; sending the coating weight, application and dimensions together with your enquiry will result in a quotation better suited to budget planning. The most suitable galvanized steel coil is the one whose grade, coating and surface condition match the processing method and the service environment — not necessarily the one with the heaviest coating or the lowest price.

    description1

    description2

    Details Image

    cs1cs4Galvanized steel coilCS45

    Our customers

    ew1new2new3new4

    Contact Us